Protecting Patient Safety and System Integrity through Precision Monitoring
Moisture isn't just water—it's a threat to your entire infrastructure. Left unmonitored, moisture in gas systems leads to critical risks:
Internal oxidation and structural decay.
Failure of sensitive medical valves.
Costly repair and cleaning cycles.
Safety hazards in clinical environments.
The ASICO-DPS sensor utilizes advanced Capacitive Polymer Technology to provide real-time sensing of moisture levels. It calculates the exact temperature at which condensation will form, allowing you to:
Prevent Bacterial Growth: Stay ahead of pathogen-thriving environments.
Ensure Compliance: Meet NFPA 99 and CSA dryness standards effortlessly.
Where accuracy is non-negotiable.
Ensure safe and dry medical air supply by continuously monitoring moisture levels. Proper dew point control helps prevent condensation, protects equipment, and supports compliance with NFPA 99 and CSA standards.
NFPA 99 / CSA STANDARDS
Maintain system efficiency and prevent corrosion by detecting moisture before it causes damage. Even small changes in dew point can significantly impact compressed air quality and equipment lifespan.
ISO 8573-1 COMPLIANCE
Support high-purity environments by controlling moisture in gas systems used in production and processing. Accurate dew point monitoring ensures product integrity and regulatory compliance.
GxP REGULATED
Maintain precise environmental conditions where even minimal moisture variations can affect results. Ideal for applications requiring high accuracy and stability in research environments.
Prevent contamination and ensure consistent product quality by monitoring moisture levels in compressed air used during production and packaging processes.
The sensor continuously monitors moisture levels in gas streams and calculates the dew point temperature—the exact moment condensation occurs.
By maintaining proper dew point levels, systems can operate efficiently without the risk of moisture damage. Our sensor provides the real-time data needed to trigger alarms before a single drop of water forms.
Measures −50°C to +50°C with ±2°C accuracy for reliable moisture control.
Response time of < 4 seconds (t90) allows for immediate corrective action.
4–20 mA linear output connects easily to Alarms, BMS, and PLC systems.
Operates in ambient temperatures from −40°C to +60°C for long-term durability.
Designed with a 3-wire configuration for quick and straightforward setup.
| Parameter | Data |
|---|---|
| Dew Point Range | −50°C to +50°C |
| Accuracy | ±2°C |
| Output Signal | 4–20 mA (Linear) |
| Supply Voltage | 10–30 VDC |
| Wiring Configuration | 3-wire system |
| Operating Temperature | −40°C to +60°C |
Designed for rapid retrofit or new facility construction.